Application
The wire is rated at 600V for underground secondary distribution not exceeding 90˚C. It may be directly buried in earth or installed in duct in both wet or dry locations.
Configuration
Black phase insulated conductors cabled with neutral. Neutral will be marked with yellow striping or yellow jacket.
Conductors: Class B compressed concentric lay stranded 1350 aluminum alloy per ASTM B231 or AA-8000 aluminum alloy per ASTM B800 & B801.
Insulation: Phase conductors in black thermoset cross-linked polyethylene (XLPE). Neutral conductor in black thermoset cross-linked polyethylene (XLPE) identified by yellow striping or full yellow jacket.
Features
Individual cables are UL Listed as USE-2
RUS accepted
Temperature rating of 90˚C dry, wet, and direct burial
Heat, ozone, oil, and chemical resistant
Tear and abrasion resistant
Standards
ICEA S-105-692: 600V Single layer thermoset insulated utility underground distribution cable
UL854: Service Entrance Cables
RUS accepted
Get all the answers to the most frequently asked questions (FAQs) regarding Secondary Aluminum URD Cable chart,Secondary Aluminum URD Cable sizes,Secondary Aluminum URD Cable full form,Secondary Aluminum URD Cable ampacity,Secondary Aluminum URD Cable diameter and much, much more.
Code Name | Size | Stranding | Insulation Thickness | Nominal Diameter | Approx. Net Weight | Ampacity NEC1 | Ampacity ICEA* |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inches | mm | Inches | mm | lb / kft. | kg/km | 60°C | 75°C | 90°C | Direct Buried2 | Pole Riser Conduit3 |
|||
SINGLE CONDUCTOR 600V SECONDARY URD |
|||||||||||||
Cornell | 8 | 7 | 0.06 | 1.52 | 0.26 | 6.6 | 34 | 51 | 40 | 44 | 49 | 74 | 36 |
Princeton | 6 | 7 | 0.06 | 1.52 | 0.3 | 7.6 | 47 | 70 | 46 | 56 | 59 | 96 | 47 |
Mercer | 4 | 7 | 0.06 | 1.52 | 0.35 | 8.9 | 67 | 100 | 63 | 72 | 81 | 117 | 60 |
Clemson | 2 | 7 | 0.06 | 1.52 | 0.41 | 10.4 | 97 | 144 | 86 | 100 | 108 | 154 | 82 |
Kenyon | 1 | 19 | 0.08 | 2.03 | 0.49 | 12.4 | 128 | 190 | 98 | 111 | 124 | 171 | 97 |
Harvard | 1/0 | 19 | 0.08 | 2.03 | 0.52 | 13.2 | 154 | 229 | 115 | 133 | 146 | 193 | 112 |
Yale | 2/0 | 19 | 0.08 | 2.03 | 0.57 | 14.5 | 186 | 277 | 132 | 150 | 162 | 221 | 132 |
Tufts | 3/0 | 19 | 0.08 | 2.03 | 0.62 | 15.7 | 225 | 335 | 150 | 172 | 189 | 253 | 155 |
Beloit | 4/0 | 19 | 0.08 | 2.03 | 0.68 | 17.3 | 274 | 408 | 173 | 200 | 221 | 290 | 185 |
Hofstra | 250 | 37 | 0.095 | 2.41 | 0.75 | 19.1 | 329 | 490 | 196 | 228 | 248 | 317 | 199 |
Gonzaga | 300 | 37 | 0.095 | 2.41 | 0.81 | 20.6 | 385 | 573 | 224 | 255 | 281 | 349 | 223 |
Rutgers | 350 | 37 | 0.095 | 2.41 | 0.85 | 21.6 | 439 | 653 | 242 | 278 | 302 | 381 | 248 |
Dartmouth | 400 | 37 | 0.095 | 2.41 | 0.9 | 22.9 | 493 | 734 | 259 | 300 | 329 | 410 | 272 |
Brown | 450 | 37 | 0.095 | 2.41 | 0.94 | 23.9 | 547 | 814 | --- | --- | --- | 439 | 295 |
Emory | 500 | 37 | 0.095 | 2.41 | 0.98 | 24.9 | 601 | 894 | 299 | 344 | 378 | 464 | 318 |
Duke | 600 | 61 | 0.11 | 2.79 | 1.09 | 27.7 | 725 | 1079 | 328 | 377 | 416 | 514 | 355 |
Furman | 700 | 61 | 0.11 | 2.79 | 1.16 | 29.5 | 830 | 1235 | 362 | 416 | 459 | 549 | 386 |
Sewanee | 750 | 61 | 0.11 | 2.79 | 1.19 | 30.2 | 883 | 1314 | 368 | 427 | 470 | 567 | 403 |
Fordham | 1000 | 61 | 0.11 | 2.79 | 1.34 | 34 | 1144 | 1702 | 431 | 494 | 540 | 665 | 492 |
Code Name | Phase Conductor | Neutral | Diameter (mils.) | Weight/kft. (lbs.) | Allowable Ampacities* |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Stranding | Insulation Thickness | AWG | Stranding | Insulation Thickness | Single Phase Cond. | Complete Cable | Direct Burial | In Ducts |
||
DUPLEX 600V SECONDARY URD |
|||||||||||
Bard | 8 | 7 | 60 | 8 | 7 | 60 | 262 | 524 | 76 | 70 | 55 |
Clafin | 6 | 7 | 60 | 6 | 7 | 60 | 298 | 596 | 91 | 95 | 70 |
Delgado | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 690 | 129 | 125 | 90 |
Everett | 2 | 7 | 60 | 2 | 7 | 60 | 403 | 806 | 189 | 187 | 100 |
TRIPLEX 600V SECONDARY URD |
|||||||||||
Erskine | 6 | 7 | 60 | 6 | 7 | 60 | 298 | 644 | 136 | 95 | 70 |
Vassar | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 745 | 194 | 125 | 90 |
Stephens | 2 | 7 | 60 | 4 | 7 | 60 | 403 | 870 | 260 | 165 | 120 |
Ramapo | 2 | 7 | 60 | 2 | 7 | 60 | 403 | 870 | 290 | 165 | 120 |
Brenau | 1/0 | 19 | 80 | 2 | 7 | 60 | 512 | 1106 | 409 | 215 | 160 |
Bergen | 1/0 | 19 | 80 | 1/0 | 19 | 80 | 512 | 1106 | 476 | 215 | 160 |
Converse | 2/0 | 19 | 80 | 1 | 19 | 80 | 555 | 1199 | 490 | 245 | 180 |
Hunter | 2/0 | 19 | 80 | 2/0 | 19 | 80 | 555 | 1199 | 540 | 245 | 180 |
Hollins | 3/0 | 19 | 80 | 1/0 | 19 | 80 | 603 | 1302 | 586 | 280 | 205 |
Sweetbriar | 4/0 | 19 | 80 | 2/0 | 19 | 80 | 658 | 1421 | 740 | 315 | 240 |
Monmouth | 4/0 | 19 | 80 | 4/0 | 19 | 80 | 658 | 1421 | 847 | 315 | 240 |
Pratt | 250 | 37 | 95 | 3/0 | 19 | 80 | 732 | 1581 | 857 | 345 | 265 |
Wesleyan | 350 | 37 | 95 | 4/0 | 19 | 80 | 831 | 1795 | 1135 | 415 | 320 |
Rider | 500 | 37 | 95 | 350 | 37 | 95 | 980 | 2117 | 1248 | 495 | 395 |
Fairfield | 750 | 61 | 110 | 500 | 37 | 95 | 1188 | 2860 | 2304 | 615 | 525 |
QUADRUPLEX 600V SECONDARY URD |
|||||||||||
Tulsa | 4 | 7 | 60 | 4 | 7 | 60 | 345 | 833 | 258 | 120 | 85 |
Dyke | 2 | 7 | 60 | 4 | 7 | 60 | 403 | 973 | 367 | 155 | 115 |
Wittenberg | 2 | 7 | 60 | 2 | 7 | 60 | 403 | 973 | 375 | 155 | 115 |
Notre Dame | 1/0 | 19 | 80 | 2 | 7 | 60 | 512 | 1236 | 574 | 200 | 150 |
Purdue | 1/0 | 19 | 80 | 1/0 | 19 | 80 | 512 | 1236 | 596 | 200 | 150 |
Syracuse | 2/0 | 19 | 80 | 1 | 19 | 80 | 555 | 1340 | 664 | 225 | 170 |
Lafayette | 2/0 | 19 | 80 | 2/0 | 19 | 80 | 555 | 1340 | 720 | 225 | 170 |
Swarthmore | 3/0 | 19 | 80 | 1/0 | 19 | 80 | 603 | 1456 | 805 | 250 | 195 |
Davidson | 3/0 | 19 | 80 | 3/0 | 19 | 80 | 603 | 1456 | 874 | 250 | 195 |
Wake Forest | 4/0 | 19 | 80 | 2/0 | 19 | 80 | 658 | 1588 | 1036 | 290 | 225 |
Earlham | 4/0 | 19 | 80 | 4/0 | 19 | 80 | 658 | 1588 | 1066 | 290 | 225 |
Rust | 250 | 37 | 95 | 3/0 | 19 | 80 | 760 | 1830 | 1213 | 325 | 210 |
Slippery Rock | 350 | 37 | 95 | 4/0 | 19 | 80 | 831 | 1945 | 1544 | 385 | 305 |
Wofford | 500 | 37 | 95 | 350 | 37 | 95 | 990 | 2390 | 2251 | 467 | 420 |
Windham | 750 | 61 | 110 | 500 | 37 | 95 | 1200 | 2890 | 3266 | 615 | 492 |