JYTOP is a leading manufacturer of Service Entrance Concentric Cable in the field of power transmission and distribution
With over 30 years production experience and 15 years export experience, factory price without any third party. Can be customized your ideal size,meets or exceeds the requirements of all international standards like ASTM, AS, BS, CSA, DIN, IEC, NFC, SS -etc.
JYTOP's Service Entrance Concentric Cable have been exported to many countries and regions such as the Middle Est, Africa, Asia Oceania, South America, North America etc., and have won praise from domestic and foreign customers.
In this page, we'll introduce Service Entrance Concentric Cable and their advantages, applications, standards and frequently asked questions.
Application
The concentric cables are used as electric service entrance from the power distribution network until the meter panel (especially where it is required to prevent “black” losses or electric power robbery), and as feeder cable from the meters panel until the panel or general distribution panel, just as it is specified in the National Electrical Code. This type of conductor can be used in dry and wet places, directly buried or outdoors; its maximum temperature of operation is 90ºC and its voltage of service for all the applications is 600v.
Conductor: Copper wire, Aluminum Wire, Aluminum Alloy Wire S8000, Copper Clad Aluminum(CCA)
Insulation: XLPE
Neutral Conductor: Copper wire, Aluminum Wire, Aluminum Alloy Wire S8000, Copper Clad Aluminum(CCA)
Binder Tape: Polyester Tape or Semi-conducting Tape
ASTM D2655, ASTM B556, ASTM B193, UL 44, UL 1581, ASTM B8, UL 854, NEC Numeral 310.14
Get all the answers to the most frequently asked questions (FAQs) regarding Service Entrance Concentric Cable chart,Service Entrance Concentric Cable sizes,Service Entrance Concentric Cable full form,Service Entrance Concentric Cable ampacity,Service Entrance Concentric Cable diameter and much, much more.
Core and nominal cross section | Conductor | Insulation thickness | Concentric conductor | Thickness of cable shield | . | Cable weight/km | Max DC resistance of conductor (20℃) | |||
---|---|---|---|---|---|---|---|---|---|---|
Wire gauge | Number | Diameter mm | mm | Number | Diameter mm | mm | mm | kg/km | Ω/km () | Ω/km (Concentric) |
Copper conductor (US standard) | ||||||||||
2X #12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 | 7.74 | 108 | 5.43 | 5.50 |
2X #10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | 8.72 | 151 | 3.41 | 3.50 |
2X #8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.74 | 214 | 2.14 | 2.20 |
2X #6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 11.04 | 313 | 1.35 | 1.40 |
2X #4 | 7 | 1.96 | 1.14 | 26 | 1.020 | 1.14 | 12.68 | 472 | 0.848 | 0.85 |
3X #8 | 7 | 1.23 | 1.14 | 65 | 0.405 | 1.14 | 11.3X17.3 | 418 | 2.14 | 2.20 |
3X #6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | 13.2X20.2 | 620 | 1.35 | 1.40 |
3X #4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | 14.7X22.9 | 875 | 0.848 | 0.85 |
3X #2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 | 16.6X26.3 | 1275 | 0.524 | 0.53 |
Aluminum alloy conductor (US standard) | ||||||||||
2X #12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 | 7.74 | 67 | 8.88 | 8.90 |
2X #10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | 8.72 | 85 | 5.59 | 5.60 |
2X #8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.74 | 110 | 3.52 | 3.60 |
2X #6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 11.04 | 148 | 2.21 | 2.30 |
2X #4 | 7 | 1.96 | 1.14 | 26 | 1.020 | 1.14 | 12.68 | 206 | 1.39 | 1.40 |
3X #8 | 7 | 1.23 | 1.14 | 65 | 0.405 | 1.14 | 11.3X17.3 | 262 | 3.52 | 3.60 |
3X #6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | 13.2X20.2 | 370 | 2.21 | 2.30 |
3X #4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | 14.7X22.9 | 488 | 1.39 | 1.40 |
3X #2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 | 16.6X26.3 | 640 | 0.88 | 0.89 |
Core and nominal cross section | Conductor | Insulation thickness | Concentric conductor | Thickness of cable shield | . | Weight of cable/km | Max DC resistance of conductor (20℃) | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
mm2 | Number | Diameter mm | mm | Number | Diameter mm | mm | mm | kg/km | Ω/km () | Ω/km (Concentric) | |
Copper conductor (IEC standard) | |||||||||||
2X10 | 7 | 1.35 | 1.55 | 20 | 0.85 | 1.40 | 11.80 | 290 | 1.83 | 1.90 | |
2X16 | 7 | 1.70 | 1.55 | 32 | 0.85 | 1.40 | 12.84 | 420 | 1.15 | 1.20 | |
2X25 | 7 | 2.14 | 1.60 | 29 | 1.13 | 1.50 | 15.02 | 630 | 0.727 | 0.76 | |
2X35 | 19 | 1.53 | 1.65 | 27 | 1.35 | 1.60 | 17.00 | 832 | 0.524 | 0.55 | |
Aluminum alloy conductor (IEC standard) | |||||||||||
2X10 | 7 | 1.35 | 1.55 | 23 | 1.13 | 1.40 | 12.41 | 192 | 3.08 | 1.335 | |
2X16 | 7 | 1.70 | 1.55 | 26 | 1.13 | 1.40 | 13.46 | 230 | 1.91 | 1.808 | |
2X25 | 7 | 2.14 | 1.6 | 29 | 1.13 | 1.50 | 15.08 | 290 | 1.20 | 1.0586 | |
2X35 | 19 | 1.53 | 1.65 | 27 | 1.35 | 1.60 | 17.05 | 370 | 0.868 | 0.7966 |
Delivers high-quality Service Entrance Concentric Cable to customers worldwide.